| - | **Transponder prüfen** | ||
| - | Transponder einschalten auf „ALT“ | ||
| - | |||
| - | Mit //Select// Cursor verschieben und mit //Slew// Wert verändern | ||
| - | |||
| - | __Setup 1__ Distanzen und Antennenwerte | ||
| - | |||
| - | Bottom (Distanzwerte in ft) | ||
| - | |||
| - | Range Height | ||
| - | |||
| - | 7 2 | ||
| - | |||
| - | Gain (Werte in DB) | ||
| - | |||
| - | 1030 1090 loss | ||
| - | |||
| - | 9.4 9.7 1.2 | ||
| - | |||
| - | __Setup 2__ Dump Test Data | ||
| - | |||
| - | Prefix String = ON | ||
| - | |||
| - | __Setup 3__ Einstellungen/ | ||
| - | |||
| - | Power (ERP) untis = WATTS | ||
| - | POS = Local | ||
| - | Diversity Test = OFF | ||
| - | Spec Serv = GICB | ||
| - | Store Data : (Mit Select Cursor verschieben und mit Slew Wert verändern) mit Run speichern. Punkt bei Zahl zeigt den erfolgreichen Speichervorgang an. | ||
| - | |||
| - | __Messung__ | ||
| - | |||
| - | PWR Test => Run (Positionieren der Antenne) | ||
| - | Instant 180-200-220 73-76-77 | ||
| - | |||
| - | Auto Test => Run | ||
| - | |||
| - | Setup 3, Messung speichern | ||
| - | |||
| - | Setup 2, Messung an PC (Hyperterminal) senden (Dump Data) | ||
| - | |||
| - | Einstellung Hyperterminal = serial COM3, dann " | ||